Endress+Hauser Levelflex FMP55 level transmitter

Monday, 02 May, 2011 | Supplied by: Endress+Hauser Australia Pty Ltd


The Levelflex FMP55 level transmitter uses both capacitance and guided wave radar technologies to measure level and the interface between two liquids.

The multiparameter level transmitter uses two level technologies built into one probe and can measure both the overall level of a liquid and the interface between two liquids. The transmitter will automatically switch between the technologies in order to provide a concise and reliable interface measurement, even in the presence of emulsion or rag layers. The use of two technologies eliminates many problems associated with interface level applications.

Capacitance is not affected by emulsion or rag layers in interface applications and the radar allows the transmitter to monitor the overall level as well as the interface level. The transmitter has a multi-echo tracking algorithm that can track up to 20 tank echoes simultaneously as the tank level rises or lowers. This ensures that the transmitter will not make a ‘jump’ to an echo that is not the true level, such as a internal tank obstruction or heater coils.

The level sensor has a measuring range of up to 10 m. The transmitter offers 4-20 mA with HART output signal plus an optional second 4-20 mA output.

With its coated multiparameter probe, the transmitter is suitable for interface measurement and it can be used in process temperatures from -50 to 200°C and in pressures from -1 to 40 bar. The device carries a SIL2 rating as certified by TÜV per IEC 61508 and has ATEX, IEC Ex, FM and CSA area classification approvals available.

The device is equipped with a HistoROM built into the main housing of the transmitter. All of the set-up parameters are stored on the HistoROM and, in the event of an electronics changeout, all of the information will be uploaded directly into the new electronics module. In the case of multiple units being set up at the same time with the same measurement parameters, the same HistoROM information can be transferred into a display that can be removed and installed in the next transmitter. This allows for the transfer of the set-up data, reducing set-up time during field commissioning.

Online: www.au.endress.com
Phone: 1300 363 707
Related Products

Key Technology conveyor systems for poultry processing and packaging

Key Technology is introducing vibratory conveying systems for poultry processing and packaging...

tna intelli-assist XR solution for food manufacturers

TNA Solutions has launched the tna intelli-assist, an immersive Industry 5.0 extended reality...

Alfa Laval ThinkTop V55 sensing and control unit for diaphragm valves

The Alfa Laval ThinkTop V55 hygienic diaphragm valve sensing and control unit is suitable for the...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd